CQ-18T
Relative Control A relative pan/balance message uses the same parameter number, but with an increment or decrement byte. Incrementing moves to the right and decrementing moves to the left.
Right one step (increment)
Increment
MSB
LSB
B0 63 MB
B0 62 LB
B0 60 00
Left one step (decrement)
Decrement
MSB
LSB
B0 63 MB
B0 62 LB
B0 61 00
Both where: MB/LB = MSB/LSB Parameter number
Examples:
Address, Left/Right
Message
Ip1 to LR, Right Ip1 to LR, Left
B0 63 50 B0 62 00 B0 60 00 B0 63 50 B0 62 00 B0 61 00 B0 63 51 B0 62 30 B0 61 00 B0 63 53 B0 62 30 B0 61 00
Ip10 to Out 1/2, Left BT to Out 5/6, Left
12
MIDI Protocol V1.2 Issue 5
Made with FlippingBook - professional solution for displaying marketing and sales documents online