RCF RDNet Control 2
RDNet 4.0 User Manual Rev. A
12.7
DMA 162P INPUTS
If the LOCAL/BUS button in the MATRIX window is on (when lit), only the LOCAL IN settings are available.
LOCAL IN
1. STEREO UNLINK When off, left and right inputs are managed as a stereo pair (left and right channels), so all setting values are exactly the same and every single adjust affects the other channel too. When on, all controls are separate and independent.
2. GAIN Gain level adjustment of its respective channel.
3. HIGH High frequency level adjustment of its respective channel.
4. MID Mid frequency level adjustment of its respective channel.
5. LOW Low frequency level adjustment of its respective channel.
6. LOCK Click the LOCK button to prevent (when lit) a configuration made via RDNet software from being messed up by a user acting on DMA 162P rear panel controls (dip-switches and trimmers). The MUTE and BUS / LOCAL contacts are excluded from the LOCK function.
If the LOCAL/BUS button in the MATRIX window is off, only the BUS settings are available.