Mounting options:

CAUTION: Mount the unit out of reach of the audience.

Ensure that the intended mounting point has sufficient load capacity. The projector's suspension devices must be constructed and rated to withstand 10 times the working load for 1 hour without permanent harmful deformation.

The unit must always be protected with a second independent fuse that complies with current regulations.

No persons must be underneath the unit when it is being installed or serviced. maintenance.

The unit must be operated at least 0.5m from the nearest flammable surface. flammable surface.

Suspended installation may only be carried out by competent persons. The permissible load capacity and the applicable regulations for event technology must be observed. Under certain conditions, acceptance by expert persons or institutions is necessary.

It must be ensured that the unit is securely mounted before it is put into operation.

If the unit is to be suspended from the ceiling or high beams, etc., truss systems must always be used. The unit must never be mounted swinging freely in the room. The unit can be placed directly on the floor or installed in any possible position in the trussing without losing its functional properties. without changing its functional characteristics. The unit is equipped with a quick-fit omega suspension bracket. This is bolted to the unit and provides a mounting hole for common clamps. When mounting this fixture to a truss, ensure that the clamp is bolted to the Omega Suspension Bracket via an M10 bolt and nut. Insert the quick-release fastener of the Omega suspension bracket into the holes provided on the underside of the unit. Turn the quick release fastener clockwise as far as it will go.

Always secure the unit with a suitable safety rope when mounting it overhead (mounting height >100 cm).

Only safety ropes and quick links according to DIN 56927, shackles according to DIN EN 1677-1 and BGV C1 warp connectors may be used. The safety ropes, quick links,shackles and warp binders must be sufficiently dimensioned on the basis of the latest occupational safety regulations (e.g. BGV C1, BGI 810-3) and used correctly.

Hang the quick-release link in the hole provided in the floor panel. Guide the safety rope over the crossbar or a safe attachment point. Hook the end into the quick link and tighten the lock nut securely.

The maximum drop distance must not exceed 20 cm.

A safety rope that has once been exposed to the load of falling or is damaged must not be used as a safety rope again.